Efficient safe easy to use.
Class a ovens and furnaces.
This standard shall apply to class a class b class c and class d ovens dryers and furnaces.
Class a ovens must have a purge period before the heat source can be energized.
Order additional factory installed options for our heratherm and vacutherm lines.
The large size and maximum 343 650 temperature of the tfd walk in ovens make these models a perfect choice for curing and drying large size or large batch components.
An oven or furnace that has heat utilization equipment operating at approximately atmospheric pressure wherein there is a potential explosion or fire hazard that could be occasioned by the presence of flammable volatiles or combustible materials processed or heated in the furnace.
This additional equipment is sized based on the volume of solvent being evaporated and the maximum operating temperature.
Browse our accessories to optimize the performance of your ovens and furnaces including oven floor stands and stacking kits furnace exhaust connections and racks and shelves.
From ovens and furnaces to dryers and thermal oxidizers a piece of equipment that breaks down hazardous gases to fend off air pollution many machines fall under the support of nfpa 86 2019.
Reserved 11 3 heating systems.
Reserved 11 4 commissioning operations maintenance inspection and testing.
Ovens are separated by class per nfpa 86.
And any other heated enclosure used for processing of materials and related equipment.
Industrial ovens and industrial furnaces in batch and conveyor configurations for thermal processing applications such as annealing curing drying heat treating sterilizing burn in and testing.
Nfpa 86 2019 pertains to class a class b class c and class d ovens dryers and furnaces as well as thermal oxidizers.
This purge period must be long enough to get at least four air changes of interior volume.
Tfd class a walk in ovens.
Nfpa 86 defines ovens for these applications as class a ovens.
Chapter 11 class a ovens and furnaces 11 1 general.
In order to keep flammable vapor concentration at safe levels class a ovens include additional equipment to provide safety ventilation.
Known for tighter temperature tolerances higher yields and consistent repeatable results.
Reserved 11 2 location and construction.
The tfd class a walk in oven is specifically designed to meet nfpa 86 requirements.
Whether you have a direct gas fired furnace or an electrically heated industrial oven understanding and following the nfpa 86 standard for ovens and furnaces can minimize the risk of a catastrophic event at your plant.
A 1 1 explosions and fires in fuel fired and electric heat utilization equipment constitute a loss potential in life property and production.
11 7 low oxygen atmosphere class a ovens with solvent recovery.